    24V LED Lighting Voltage Drop: Cable Size and Run-Length Planning for GU10, MR16 and A60

    24V LED Lighting Voltage Drop: Cable Size and Run-Length Planning for GU10, MR16 and A60

    The first 24V LED bulb on a lighting circuit works perfectly. The last one flickers, looks dimmer or occasionally switches off.

    It’s tempting to blame the bulb, especially when every lamp has the same voltage and wattage rating. But on a long cable run, the voltage reaching the last fixture is lower than the voltage measured at the power supply.

    This is voltage drop, and it needs attention before the wiring is installed.

    A 24V system carries more current than a mains-voltage system delivering the same power. Cable resistance therefore becomes important in decorative lighting installations, particularly where several GU10, MR16 or A60 bulbs share a low-voltage circuit.

    You don’t need complicated calculations to identify the problem. You need the correct cable length, load current and bulb input specifications.

    Collect the Inputs Before Choosing a Cable

    24V GU10, MR16 and A60 LED bulbs with copper cables and example parameters for cable sizing and circuit planning.

    Before selecting a cable size, find out how much current the circuit will carry and how far it has to travel.

    Start with the actual one-way cable length from the power supply or controller output to the load. A straight-line measurement on a floor plan isn’t enough. The cable might run along a ceiling, around structural elements or through several junction boxes before reaching the final fixture.

    Use the planned cable route, not the shortest distance between two points.

    Next, calculate the total connected load using the bulbs’ rated input power. You’ll need this figure to determine the current flowing through the cable.

    Also check the conductor material and cross-sectional area. Copper is commonly used in low-voltage lighting circuits, but 1.5mm² and 2.5mm² copper conductors have different resistance values.

    Temperature changes the calculation. Copper resistance increases as the conductor becomes hotter, so a cable operating in a warm ceiling space has greater resistance than the same cable at 20°C.

    Don’t overlook the connections.

    Terminal blocks, connectors and poorly made joints introduce additional resistance. A long circuit with several connections can lose more voltage than a calculation based on cable resistance alone suggests.

    Finally, check the LED bulb’s permitted input voltage range.

    A lamp marked 24V DC doesn’t necessarily operate normally at 22V or 23V. Some bulbs have a wider operating range, while others require an input closer to their nominal voltage.

    The minimum specified input voltage determines how much voltage loss the installation can tolerate before operation falls outside the manufacturer’s requirements.

    If you’re using PWM dimming, include the controller’s output characteristics and any specified cable-length limits in the design.

    Calculate the Complete Supply-and-Return Path

    24V DC power supply connected to three GU10 LED bulbs with supply and return cables and a voltage drop formula.

    The most common voltage-drop mistake is calculating resistance using only the distance from the power supply to the lamp.

    Current has to return to the supply.

    In a conventional two-conductor DC circuit, both the positive and negative conductors contribute resistance.

    For a simple circuit with a concentrated load at the far end, the voltage drop can be estimated as:

    ΔV = 2 × L × I × ρ ÷ A

    Here, ΔV is the voltage drop in volts, L is the one-way cable length in meters, I is the circuit current in amperes, ρ is the conductor resistivity in Ω·mm²/m, and A is the conductor cross-sectional area in mm².

    The factor of two accounts for the outgoing and return conductors, assuming they have the same length and cross-section.

    For copper at approximately 20°C, a commonly used resistivity value is 0.0172 Ω·mm²/m.

    This formula works as a first estimate for a two-wire circuit with its load concentrated at the far end.

    A real lighting installation often looks different.

    Imagine ten pendant lamps spaced along a corridor. The first cable section carries the current for all ten lamps. After the first branch, the remaining cable carries the current for nine. Each successive section carries less current.

    Applying the total circuit current to the entire cable length would overestimate the cable drop for this distributed arrangement.

    Instead, calculate the voltage drop across each section using the current flowing through that section, then add the drops along the path to the fixture you’re checking.

    The same principle applies when branches have different cable lengths or conductor sizes.

    If the positive and return conductors follow different routes, calculate their resistance separately rather than automatically multiplying one length by two.

    Compare 1.5mm² and 2.5mm² in a Worked Example

    Suppose a decorative lighting circuit uses eight 24V LED bulbs rated at 4W each.

    The total nominal load is 32W, and the one-way cable distance to the load is 20 meters.

    We’ll treat the bulbs as a single load at the far end, use copper conductors at 20°C, and ignore connector resistance for this comparison.

    Eight 4W bulbs have a combined nominal load of 32W. At 24V, that gives a nominal current of 32 ÷ 24 ≈ 1.33A.

    With 1.5mm² copper cable, the calculated voltage drop is approximately 0.61V.

    Assuming the power supply delivers exactly 24V at its terminals, the estimated load voltage is 23.39V.

    Change to 2.5mm² copper cable and the drop falls to approximately 0.37V, leaving about 23.63V at the load.

    That’s a difference of roughly 0.24V between the two cable sizes.

    Neither result automatically tells you whether the installation is acceptable.

    If the bulbs are specified to operate throughout the resulting voltage range, both arrangements may work. If their minimum input voltage is close to 24V, even the larger cable might not provide enough margin once temperature, connections and supply tolerances are included.

    The example assumes a fixed nominal current of approximately 1.33A. Real LED bulbs contain driver electronics, and their current draw can change as input voltage falls.

    These figures are useful for comparing cable resistance, not for predicting every bulb’s exact behavior.

    Cable current rating and voltage drop are also two separate checks.

    A cable may have enough current-carrying capacity for the connected load but still produce excessive voltage drop over a long run.

    The reverse is also possible. A short cable run may have very little voltage drop, yet its conductor is unsuitable for the current or installation conditions.

    Check the cable’s permitted current rating against the installation method, ambient temperature, grouping and protective device. Then verify that the voltage reaching the furthest bulb remains within its specified input range.

    Passing one check doesn’t mean the other is satisfied.

    The example above is not a regulatory recommendation for either cable size. Final conductor selection must meet the applicable electrical requirements.

    Choose Between Thicker Cable and Shorter Circuits

    Comparison of a 20-metre LED lighting circuit and two illustrated 10-metre circuit sections.

    Increasing conductor size reduces resistance, but shorter cable runs often provide a more practical solution.

    Moving the 24V supply closer to the fixtures or dividing a long lighting run into smaller circuits reduces the cable length and current carried by each section.

    The best arrangement depends on fixture positions, cable routes and required control zones. Keep power supplies accessible and within their specified temperature limits.

    For power supply capacity, startup behavior and circuit separation, see our guide to [sizing a 24V DC power supply for LED bulbs]

    PWM-controlled installations have another constraint.

    Some LED controllers specify a maximum cable length between the controller and the lamps. That limit is based on particular wiring and load conditions, not a universal distance that applies to every installation.

    Changing the cable size, number of connected bulbs or bulb driver design changes the electrical characteristics of the circuit. A published maximum length shouldn’t be treated as approval for every combination of 24V lamps and wiring.

    Check the controller manufacturer’s specified conditions, particularly when several lamps share one channel. If the manufacturer sets a maximum permitted length, don’t exceed it simply because a voltage-drop calculation looks acceptable.

    Also verify the maximum current per controller channel and the ratings of the terminals carrying that current.

    If you’re integrating 24V GU10 lighting with a building-control system, our guide to [sizing a 24V DC power supply for LED bulbs] explains why the controller’s actual output type and PWM compatibility matter.

    Check the Furthest Lamp Under Load

    Calculations get you close. Measurements tell you what the installed circuit is actually delivering.

    With the complete lighting circuit operating at its maximum expected load, measure the voltage at the power supply output and at the furthest fixture.

    The difference reveals the voltage lost along the installed wiring, including connections.

    Make sure the measurement is taken at the bulb input or an appropriate accessible test point. Measuring only at the supply terminals misses the losses along the route.

    Don’t assume that a visibly bright bulb is receiving its rated voltage.

    Many 24V LED bulbs contain internal current-regulation circuitry. As the input voltage falls, the driver maintains LED current and brightness within its supported operating range.

    The bulb may look normal until the available input voltage reaches the driver’s lower operating limit.

    Then its behavior changes abruptly. The lamp begins flickering, dims sharply or switches off.

    This explains why voltage drop doesn’t always produce a gradual brightness difference along a row of LED fixtures.

    Test the complete circuit, including the control equipment.

    If PWM dimming is used, check both full output and low brightness. A PWM-compatible bulb that behaves normally on a short test cable may respond differently at the end of a long installation.

    Be careful when interpreting voltage measurements on PWM outputs.

    A PWM controller rapidly switches its output, so an ordinary multimeter reading across that output isn’t necessarily the bulb’s steady DC supply voltage. The reading depends on the waveform and the meter’s measurement method.

    Check the power supply voltage under full load. Where necessary, use an appropriate oscilloscope or other suitable measurement method to examine the PWM output and voltage at the lamp.

    Switch adjacent lighting circuits on and off while observing the furthest lamp. Shared supply capacity, distribution wiring or control arrangements can introduce interactions that aren’t obvious when only one group is operating.

    If the last lamp behaves differently, compare its input voltage and dimming response with a fixture closer to the supply.

    Where the voltage is below the bulb’s specified input range, address the cable resistance, distribution layout or supply arrangement before replacing bulbs at random.

    And don’t compensate by raising the power supply voltage without checking the maximum permitted input of every connected lamp. The nearest fixtures will receive the highest voltage.

    Record the results before handing over the installation.

    Keep the measured voltage at the furthest fixture, full-load and low-dimming test results, cable sizes, lamp positions and controller model with the project documentation.

    If a bulb is replaced or another fixture is added later, these records provide a reference for checking whether the circuit still operates within its original design limits.

    Our guide to [sizing a 24V DC power supply for LED bulbs],covers replacement verification and project handover in more detail.

    A well-designed 24V circuit keeps every bulb within its electrical operating limits under the intended load and control conditions.

    Need Help Checking a 24V LED Cable Run?

    Recessed GU10 LED spotlights with a circuit design checklist showing load, cable size, run length and allowable voltage drop.

    Send Tecolite your cable lengths, bulb wattages, number of fixtures and their positions along the circuit.

    Include the conductor size, power supply specification and PWM controller model if available.

    You can also use our 24V LED Voltage Drop Input Sheet to organize the cable lengths, load currents and fixture distribution before requesting a review.

    We’ll help you check the bulb requirements and identify suitable GU10, MR16 or A60 samples for your low-voltage lighting project.

    Potenzia la tua attività con i nostri servizi di alta qualità

    Blog correlato

    pexels-photo-3760069-3760069.jpg

    Comunicateci la vostra richiesta di informazioni

    Risponderemo immediatamente alla vostra richiesta!

    Contatta rapidamente la fabbrica

    CONTATTACI

    Compila il modulo sottostante e ti contatteremo a breve.